Dimplex warranty background

First Time Use & Tips

Your installation location should meet the following requirements:

  • Make sure that you install your unit on an even surface to minimize noise and vibration.
  • The unit must be installed near a sufficient power outlet, and if using a continuous drainage method, then the plug areas should be accessible.
  • The unit should be located at least 50cm from the nearest wall to ensure proper air circulation. The horizontal louvre blade should be at least 50cm away from obstacles.
  • The exhaust hose can be extended, however it's best to keep it to the minimum length required. Ensure the hose doesn’t have any sharp bends, sagging areas, or kinks.
  • DO NOT cover the Intakes, outlets or remote control signal receptor of the unit, as this could cause damage to the unit.

A - Operation Mode

B - Temperature Down

C - Power On/

D - Temperature Up

E - Fan Speed

1 - Cooling Mode

2 - Dehumidifying Mode

3 - Fan Mode

4 - Temperature Display Area

5 - Auto Wind

6 - Low Fan Speed

7 - Medium Fan Speed

8 - High Fan Speed

ON/OFF
Press to turn the unit on/off.

MODE
Press the MODE button to select the appropriate operating MODE. The modes that can be selected, follow this sequence COOL > FAN and DRY. The selected mode indicator light will illuminate on the control panel.

FAN MODE
Press the MODE button until the FAN indicator light comes on. Press the FAN SPEED button on the remote controller to choose the fan speed. The temperature cannot be adjusted in this mode, only the fan speed. The exhaust hose needs to be removed during FAN MODE operation.

Up (-) / Down (+)
The Up (+) and Down (-) buttons are used to adjust (increase/decrease) the temperature settings in 1°C increments. The temperature range can be set from 17°C to 30°C.
NOTE: The control panel is capable of displaying the temperature in either degrees Fahrenheit or degrees Celsius. To convert from one to the other, press and hold the Up and Down buttons at the same time for 3 seconds.

COOL MODE
Press the MODE button until the COOL indicator light comes on. Press the Up (+) or Down (-) buttons to select the desired room temperature. Press the FAN SPEED button to choose to adjust the fan speed. The exhaust hose needs to be used during COOL MODE operation.

DRY / DEHUMIDIFY
Press the MODE button until the DRY indicator light comes on. The fan speed or temperature cannot be set during DRY MODE. The fan will automatically operate at LOW speed. NOTE: Keep windows and doors closed. The exhaust hose needs to be removed during DRY MODE operation.

See below:

1. Open the battery cover of the remote control, and insert 2 x AAA batteries.

2. Please point to the receiver and be within 5m when using the remote control.

3. If the battery voltage is low, please open the battery cover as per the diagram and replace with a new batteries (2 x AAA). Then replace the battery cover.

  • Be sure to clean the air filter every week of operation for optimal performance.
  • The water collection tray should be drained immediately after "E2" error occurs, and before storage to prevent mould.
  • In households with animals, you will have to periodically wipe down the grill to prevent blocked airflow due to animal hair.